HMCP050K2C - Eaton - Molded Case Circuit Breaker Feed-Thru - 50 Amp - 3 Pole - 600 Volt

Cutler Hammer molded case circuit breaker three phase and three pole 50 Ampere F frame type circuit breaker compact easy to install built in features like molded case thermal magnectic feed-thru connection (I) Instantaneous trip functions complete with non-interchangeable trip with standard line & load side lug terminals motor circuit protector and motor fla 11.5 to 42.1amp magnetic only molded case circuit breakers

HMCP150T4C - Eaton - Molded Case Circuit Breaker Feed-Thru - 150 Amp - 3 Pole - 600 Volt

The Eaton HMCP150T4C is a 3 Pole magnetic molded case circuit breaker with a current rating of 150 Amps and a voltage rating of 600VAC, 250VDC. It has an interrupting rating of 65kA@480V. The HMCP150T4C has a feed-thru connection type and includes I - instantaneous functions.

HMCP250W5C - Eaton - Molded Case Circuit Breaker Feed-Thru - 250 Amp - 3 Pole - 600 Volt

The Eaton HMCP250W5C is a 3 Pole magnetic molded case circuit breaker with a current rating of 250 Amps and a voltage rating of 600V. It has an interrupting rating of 35kA@480V. The HMCP250W5C has a feed-thru connection type and includes I - instantaneous functions.

HMDL3800 - Eaton - Molded Case Circuit Breaker Feed-Thru - 800 Amp - 3 Pole - 600 Volt

The Eaton HMDL3800 is a molded case circuit breaker. This type HMDL circuit breaker is a member of The series C family. The HMDL3800 is a 3 pole, 600 Volt, 800 amp rated circuit breaker, with an AIC rating of 65kA@480V and is manufactured by Eaton, Cutler Hammer and Westinghouse. The HMDL3800 uses a feed-thru connection and includes thermal magnetic protection. The trip unit features LI - Long-Time and Instantaneous functions.

HMXD63B800 - Siemens - Molded Case Circuit Breaker Bolt-on - 800 Amp - 3 Pole - 600 Volt

Siemens sentron series three pole 800 ampere bolt-on molded case circuit breaker with maximum voltage rating of 600V trip type fixed thermal magnetic and high interrupting rating of 65 kiloampere at 480V functions long-time and instantaneous complete with load side lug terminals.

HND312T36W - Eaton - Molded Case Circuit Breaker Bolt-On - 1200 Amp - 3 Pole - 600 Volt

Cutler Hammer C series HND frame 1200 ampere soild state bolt-on molded case circuit breaker with maximum voltage rating of 600V trip type LSIG electronic standard interrupting rating of 65 kiloampere at 480V functions long-time short time instantaneous and ground fault protection.

HOM115PCAFI - Square D Homeline - Arc Fault (AFCI) Circuit Breaker Plug-In - 15 Amp - 1 Pole - 120 Volt

MINIATURE THERMAL MAGNETIC TYPE 1 INCH W X 2.98 INCH D X 3.13 INCH H SIZE LOADCENTER USED ON (1) 14 TO 8 AWG (COPPER/ALUMINUM) (2) 14 TO 10 AWG (COPPER) WIRE SIZE UL APPROVAL HACR APPLICATION 120 VAC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING SCREW CLAMP TERMINAL TYPE 1 POLES ARC FAULT CIRCUIT INTERRUPTER CONSTRUCTION FEATURE HOMELINE BRAND

HOM120GFI - Square D Homeline - GFCI Circuit Breaker Plug-In - 15 Amp - 1 Pole - 120 Volt

MINIATURE THERMAL MAGNETIC TYPE 1 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOADCENTER USED ON 14 TO 10 AWG (ALUMINUM/COPPER) WIRE SIZE UL CSA APPROVAL 120 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 1 POLE(S) SCREW CLAMP TERMINAL TYPE 6 MILLIAMP TRIP SENSITIVITY HOMELINE BRAND ROHS COMPLIANT APPLICATION HEATING AIR CONDITIONING REFRIGERATION HOM-GFI MODEL

HOM120PCAFI - Square D Homeline - Arc Fault (AFCI) Circuit Breaker Plug-In - 20 Amp - 1 Pole - 120 Volt

The CAFCI breaker effectively stops the flow of current before an electrical fire from dangerous arcing can start. Typical causes of dangerous arc faults in a residence are: cord insulation damage from furniture, drywall screw piercing insulation, punctured cable by nail or staple. A standard feature in all HomeLine CAFCI circuit breakers is the TIME SAVER diagnostics test that assists in identifying the type of fault that last occurred in a circuit. It saves money by reducing troubleshooting time, simple to use and requires no tools.

HOM120PDF - HomeLine 20 Amp Dual Function Circuit Breaker Plug-In - 20 Amp - 1 Pole - 120 Volt

Schneider Electric / Square D 1 pole circuit breakers comes with the current rating of 20A and voltage rating of 120 VAC. It features an interrupt rating of 10kA at 120 VAC and has an thermal magnetic protection type. It has a combination of ARC-fault and ground fault class A with 6 mA trip sensitivity and plug-on neutral connection type. This Breaker is UL listed and HACR rated.

HOM2100 - Square D Homeline - Circuit Breaker Plug-In - 100 Amp - 2 Pole - 240 Volt

STANDARD COMMON TRIP TYPE 1 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOAD CENTER USED ON 4 TO 2/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 100 AMP CURRENT RATING 1 POLE(S) BOX LUG TERMINAL TYPE HOMELINE BRAND ROHS COMPLIANT TEMPERATURE RATING 104 DEG F APPLICATION HEATING AIR CONDITIONING REFRIGERATION

HOM2125 - Square D Homeline - Circuit Breaker Plug-In - 125 Amp - 2 Pole - 240 Volt

STANDARD COMMON TRIP TYPE 1 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOAD CENTER USED ON 4 TO 2/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 125 AMP CURRENT RATING 1 POLE(S) BOX LUG TERMINAL TYPE HOMELINE BRAND ROHS COMPLIANT TEMPERATURE RATING 104 DEG F APPLICATION HEATING AIR CONDITIONING REFRIGERATION

HOM215GFI - Homeline 15 Amp Ground Fault Circuit Breaker Plug-In - 15 Amp - 2 Pole - 240 Volt

COMMON TRIP MINIATURE TYPE LOAD CENTER USED ON 14 TO 6 AWG (COPPER) 12 TO 4 AWG (ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 2 POLE(S) SCREW CLAMP TERMINAL TYPE 6 MILLIAMP TRIP SENSITIVITY HOMELINE[TM] BRAND

HOM220 - Square D Homeline - Circuit Breaker Plug-In - 20 Amp - 2 Pole - 240 Volt

STANDARD TYPE 2 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 8 AWG (ALUMINUM/COPPER) 14 TO 10 AWG (COPPER) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) CLAMP TERMINAL TYPE HOMELINE BRAND ROHS COMPLIANT OPERATING TEMPERATURE RATING 104 DEG F NUMBER OF SPACES 2 APPLICATION HEATING AIR CONDITIONING REFRIGERATION

HOM220GFI - Square D Homeline - GFCI Circuit Breaker Plug-In - 20 Amp - 2 Pole - 240 Volt

COMMON TRIP TYPE 2 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOAD CENTER USED ON 12 TO 4 AWG (ALUMINUM) 14 TO 6 AWG (COPPER) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 20 AMP CURRENT RATING 2 POLE(S) SCREW CLAMP TERMINAL TYPE 6 MILLIAMP TRIP SENSITIVITY HOMELINE BRAND ROHS COMPLIANT AMBIENT TEMPERATURE RATING 104 DEG F APPLICATION HEATING AIR CONDITIONING REFRIGERATION

HOM230 - Square D Homeline - Circuit Breaker Plug-In - 30 Amp - 2 Pole - 240 Volt

STANDARD TYPE 2 INCH WIDTH X 2.98 INCH DEPTH X 3.13 INCH HEIGHT SIZE LOAD CENTER USED ON 14 TO 8 AWG (ALUMINUM/COPPER) 14 TO 10 AWG (COPPER) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-IN MOUNTING 10 KILOAMP INTERRUPTING RATING 30 AMP CURRENT RATING 2 POLE(S) CLAMP TERMINAL TYPE HOMELINE BRAND ROHS COMPLIANT OPERATING TEMPERATURE RATING 104 DEG F NUMBER OF SPACES 2 APPLICATION HEATING AIR CONDITIONING REFRIGERATION